<![CDATA[Beijing Care Corporation Limited]]>http://www.tradevv.com/chinasuppliers/bcc2000en-ustradevv.com<![CDATA[Sell SDi-TOF-MS-2000]]>http://www.tradevv.com/chinasuppliers/bcc2000/offers-detail-6308b/Sell-SDi-TOF-MS-2000.html]]>&lt;P class=MsoBodyText style=&quot;MARGIN: 12pt 0cm 0pt; LINE-HEIGHT: 14pt; mso-para-margin-top: 1.0gd; mso-line-height-rule: exactly&quot;&gt;&lt;B style=&quot;mso-bidi-font-weight: normal&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 12pt; mso-bidi-font-family: Arial&quot;&gt;&lt;FONT face=Arial&gt;The Mass Spectrometer&lt;?xml:namespace prefix = o ns = &quot;urn:schemas-microsoft-com:office:office&quot; /&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/FONT&gt;&lt;/SPAN&gt;&lt;/B&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;FONT face=Arial&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;The Selective Dual Input (SDI) instrument is an on-line time-of-flight mass &lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;spectrometer&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;(TOFMS) providing rapid and sensitive gas analysis for environmental&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt; or processing&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt; monitoring and research applications. &lt;/SPAN&gt;&lt;/FONT&gt;&lt;/P&gt;&lt;FONT face=Arial&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt; &lt;P class=MsoBodyText style=&quot;MARGIN: 12pt 0cm 0pt; LINE-HEIGHT: 14pt; mso-para-margin-top: 1.0gd; mso-line-height-rule: exactly&quot;&gt;&lt;B style=&quot;mso-bidi-font-weight: normal&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 12pt; mso-bidi-font-family: Arial&quot;&gt;Analytical Modes&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/B&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;The SDI-TOF-MS&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;-2000&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt; is highly attractive because it offers real-time, high time resolution, high sensitivity detection of all gas species in parallel. All masses are collected, preserving the maximum amount of information.&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;B style=&quot;mso-bidi-font-weight: normal&quot;&gt;&lt;I style=&quot;mso-bidi-font-style: normal&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;Mass Spectra&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/I&gt;&lt;/B&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;The instrument will generate single mass spectra from 0.5 seconds to many minutes duration if required. &lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;B style=&quot;mso-bidi-font-weight: normal&quot;&gt;&lt;I style=&quot;mso-bidi-font-style: normal&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;High Time Resolution Mode&lt;/SPAN&gt;&lt;/I&gt;&lt;/B&gt;&lt;B style=&quot;mso-bidi-font-weight: normal&quot;&gt;&lt;I style=&quot;mso-bidi-font-style: normal&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/I&gt;&lt;/B&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;In this mode for instance, it is possible to request full mass spectra at time slices of as little as 100ms. Alternatively, one might request the time evolution plot of any species with a time resolution of 100ms. This type of functionality is useful for extracting the most information from short-term experiments&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;.&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;B style=&quot;mso-bidi-font-weight: normal&quot;&gt;&lt;I style=&quot;mso-bidi-font-style: normal&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;Process Monitor Mode&lt;/SPAN&gt;&lt;/I&gt;&lt;/B&gt;&lt;B style=&quot;mso-bidi-font-weight: normal&quot;&gt;&lt;I style=&quot;mso-bidi-font-style: normal&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/I&gt;&lt;/B&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;Where the experiment takes places over many hours or even days, &lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;t&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;he instrument operates in a mode where selected species are plotted 'live' to a graph as a function of elapsed experiment time&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt; &lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;essentially a process monitor type operation. &lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/FONT&gt;&amp;nbsp;&lt;/P&gt;2009-9-7 10:48:42<![CDATA[SDi-TOF-MS-2000]]>http://www.tradevv.com/chinasuppliers/bcc2000/products-detail/china-SDi-TOF-MS-2000-6308a.html]]>&lt;P class=MsoBodyText style=&quot;MARGIN: 12pt 0cm 0pt; LINE-HEIGHT: 14pt; mso-para-margin-top: 1.0gd; mso-line-height-rule: exactly&quot;&gt;&lt;B style=&quot;mso-bidi-font-weight: normal&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 12pt; mso-bidi-font-family: Arial&quot;&gt;&lt;FONT face=Arial&gt;The Mass Spectrometer&lt;?xml:namespace prefix = o ns = &quot;urn:schemas-microsoft-com:office:office&quot; /&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/FONT&gt;&lt;/SPAN&gt;&lt;/B&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;FONT face=Arial&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;The Selective Dual Input (SDI) instrument is an on-line time-of-flight mass &lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;spectrometer&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;(TOFMS) providing rapid and sensitive gas analysis for environmental&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt; or processing&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt; monitoring and research applications. &lt;/SPAN&gt;&lt;/FONT&gt;&lt;/P&gt;&lt;FONT face=Arial&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt; &lt;P class=MsoBodyText style=&quot;MARGIN: 12pt 0cm 0pt; LINE-HEIGHT: 14pt; mso-para-margin-top: 1.0gd; mso-line-height-rule: exactly&quot;&gt;&lt;B style=&quot;mso-bidi-font-weight: normal&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 12pt; mso-bidi-font-family: Arial&quot;&gt;Analytical Modes&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/B&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;The SDI-TOF-MS&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;-2000&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt; is highly attractive because it offers real-time, high time resolution, high sensitivity detection of all gas species in parallel. All masses are collected, preserving the maximum amount of information.&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;B style=&quot;mso-bidi-font-weight: normal&quot;&gt;&lt;I style=&quot;mso-bidi-font-style: normal&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;Mass Spectra&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/I&gt;&lt;/B&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;The instrument will generate single mass spectra from 0.5 seconds to many minutes duration if required. &lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;B style=&quot;mso-bidi-font-weight: normal&quot;&gt;&lt;I style=&quot;mso-bidi-font-style: normal&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;High Time Resolution Mode&lt;/SPAN&gt;&lt;/I&gt;&lt;/B&gt;&lt;B style=&quot;mso-bidi-font-weight: normal&quot;&gt;&lt;I style=&quot;mso-bidi-font-style: normal&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/I&gt;&lt;/B&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;In this mode for instance, it is possible to request full mass spectra at time slices of as little as 100ms. Alternatively, one might request the time evolution plot of any species with a time resolution of 100ms. This type of functionality is useful for extracting the most information from short-term experiments&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;.&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;B style=&quot;mso-bidi-font-weight: normal&quot;&gt;&lt;I style=&quot;mso-bidi-font-style: normal&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;Process Monitor Mode&lt;/SPAN&gt;&lt;/I&gt;&lt;/B&gt;&lt;B style=&quot;mso-bidi-font-weight: normal&quot;&gt;&lt;I style=&quot;mso-bidi-font-style: normal&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/I&gt;&lt;/B&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;Where the experiment takes places over many hours or even days, &lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;t&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;he instrument operates in a mode where selected species are plotted 'live' to a graph as a function of elapsed experiment time&lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt; &lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial&quot;&gt;essentially a process monitor type operation. &lt;/SPAN&gt;&lt;SPAN lang=EN-GB style=&quot;FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial; mso-fareast-language: ZH-CN&quot;&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/P&gt; &lt;P class=MsoBodyText style=&quot;TEXT-JUSTIFY: inter-ideograph; MARGIN: 8.4pt 0cm 0pt; LINE-HEIGHT: 14pt; TEXT-ALIGN: justify; mso-para-margin-top: .7gd; mso-line-height-rule: exactly&quot;&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/SPAN&gt;&lt;/FONT&gt;&amp;nbsp;&lt;/P&gt;2009-7-8 16:08:08<![CDATA[Sell Continuous Emission Monitoring System (BKS3000)]]>http://www.tradevv.com/chinasuppliers/bcc2000/offers-detail-60e5c/Sell-Continuous-Emission-Monitoring-System-BKS3000.html]]>BKS-3000 Continuous Emission Monitoring System (CEMS) developed by our company adopts the most advanced infrared analyzing technology in the world, measuring the stack gas concentration with non-dispersive infrared absorption and the particulate matter with dynamic detection principle, the flow velocity of the flue gas measured with Pitot tube, the content of oxygen with paramagnetic oxygen analyzer. It realized continuous monitoring to the emission and total amount of gases. The control computer can dispose and store the measured data, and communicate with the environmental protection departments via the network. The environmental protection departments can collect the measured data conveniently and quickly. The BKS-3000III CEMS provides wide application, including in the power, metallurgy, pharmaceutical, iron and steel industry, fertilizer, glass, cement manufacturing and environmental protection field, etc.2009-9-7 10:48:42<![CDATA[Continuous Emission Monitoring System (BKS3000)]]>http://www.tradevv.com/chinasuppliers/bcc2000/products-detail/china-Continuous-Emission-Monitoring-System-BKS3000-60e5b.html]]>BKS-3000 Continuous Emission Monitoring System (CEMS) developed by our company adopts the most advanced infrared analyzing technology in the world, measuring the stack gas concentration with non-dispersive infrared absorption and the particulate matter with dynamic detection principle, the flow velocity of the flue gas measured with Pitot tube, the content of oxygen with paramagnetic oxygen analyzer. It realized continuous monitoring to the emission and total amount of gases. The control computer can dispose and store the measured data, and communicate with the environmental protection departments via the network. The environmental protection departments can collect the measured data conveniently and quickly. The BKS-3000III CEMS provides wide application, including in the power, metallurgy, pharmaceutical, iron and steel industry, fertilizer, glass, cement manufacturing and environmental protection field, etc.2009-9-7 10:39:51<![CDATA[Sell Gas Cooler (KRS-3000)]]>http://www.tradevv.com/chinasuppliers/bcc2000/offers-detail-60dbe/Sell-Gas-Cooler-KRS-3000.html]]>&lt;P&gt;Application: &lt;BR&gt;Electrical power industry &lt;BR&gt;Chemical engineering industry&lt;BR&gt;Textile industry&lt;BR&gt;Cement industry&lt;BR&gt;Waste incineration plant&lt;BR&gt;Heating boiler&lt;/P&gt; &lt;P&gt;FEATURES: &lt;BR&gt;1. Simple and cabinet structure. &lt;BR&gt;2. Single evaporator and two channels, concurrent processing two channels sample gases. &lt;BR&gt;3. Large volume sample gases processing. &lt;BR&gt;4. Automatic regulation, Constant temperature refrigeration. &lt;BR&gt;5. Easy maintenance and simple operation. &lt;BR&gt;6. Invalidation warning.&lt;/P&gt;2009-9-7 10:48:42<![CDATA[Sell Flue Gas Moisture Analyzer (KSD-1000)]]>http://www.tradevv.com/chinasuppliers/bcc2000/offers-detail-60eb9/Sell-Flue-Gas-Moisture-Analyzer-KSD-1000.html]]>&lt;P&gt;KSD-1000 flue gas moisture analyzer developed by Beijing Care Corporation Ltd, which is applied in directly measuring the humidity of flue gas, is precise with low use-cost and maintenance work. &lt;/P&gt; &lt;P&gt;Application: &lt;BR&gt;1. Large-scale Power Plant &amp;amp; Heat-engine Plant&lt;BR&gt;2. Industry Boiler, Heating Boiler&lt;BR&gt;3. Organic Chemical Plant&lt;BR&gt;4. Waste Incineration Plant&lt;/P&gt; &lt;P&gt;Technical Specifications: &lt;BR&gt;1. Sampling: Direct Measurement&lt;BR&gt;2. Analyze Method: Capacitance analysis&lt;BR&gt;3. Output Signal: 4-20 mA&lt;BR&gt;4. Rang: 0-20%, 0-40%, 0-60% (optional)&lt;/P&gt; &lt;P&gt;Features: &lt;BR&gt;1. High temperature resistant, and anticorrosive for both acid and alkali&lt;BR&gt;2. High precision and fast response&lt;BR&gt;3. Reliable installation, easy and convenient disassembly&lt;BR&gt;4. Suitable for harsh ambient environment&lt;BR&gt;5. On-line single point calibration&lt;BR&gt;6. Volume percentage output according with standard HJ/T76-2001 of national environmental protection industry&lt;/P&gt;2009-9-7 10:48:42<![CDATA[Sell Multi-Gas Analyzer (MGA-3000)]]>http://www.tradevv.com/chinasuppliers/bcc2000/offers-detail-60ec7/Sell-Multi-Gas-Analyzer-MGA-3000.html]]>The MGA-3000 Multi-Gas Analyzer adopts international advanced Non Dispersive Infrared&lt;BR&gt;Absorption technology. The greatest features are: &lt;BR&gt;1. High-precision, high sensitivity; &lt;BR&gt;2. With functions of Temperature, Pressure and Non-linearity compensations; &lt;BR&gt;3. The biggest measurement range of choices; &lt;BR&gt;4. Good stability, small drift.2009-9-7 10:48:42<![CDATA[Flue Gas Moisture Analyzer (KSD-1000)]]>http://www.tradevv.com/chinasuppliers/bcc2000/products-detail/china-Flue-Gas-Moisture-Analyzer-KSD-1000-60eb8.html]]>&lt;P&gt;KSD-1000 flue gas moisture analyzer developed by Beijing Care Corporation Ltd, which is applied in directly measuring the humidity of flue gas, is precise with low use-cost and maintenance work. &lt;/P&gt; &lt;P&gt;Application: &lt;BR&gt;1. Large-scale Power Plant &amp;amp; Heat-engine Plant&lt;BR&gt;2. Industry Boiler, Heating Boiler&lt;BR&gt;3. Organic Chemical Plant&lt;BR&gt;4. Waste Incineration Plant&lt;/P&gt; &lt;P&gt;Technical Specifications: &lt;BR&gt;1. Sampling: Direct Measurement&lt;BR&gt;2. Analyze Method: Capacitance analysis&lt;BR&gt;3. Output Signal: 4-20 mA&lt;BR&gt;4. Rang: 0-20%, 0-40%, 0-60% (optional)&lt;/P&gt; &lt;P&gt;Features: &lt;BR&gt;1. High temperature resistant, and anticorrosive for both acid and alkali&lt;BR&gt;2. High precision and fast response&lt;BR&gt;3. Reliable installation, easy and convenient disassembly&lt;BR&gt;4. Suitable for harsh ambient environment&lt;BR&gt;5. On-line single point calibration&lt;BR&gt;6. Volume percentage output according with standard HJ/T76-2001 of national environmental protection industry&lt;/P&gt;2009-7-2 15:26:00<![CDATA[Gas Cooler (KRS-3000)]]>http://www.tradevv.com/chinasuppliers/bcc2000/products-detail/china-Gas-Cooler-KRS-3000-60dbd.html]]>&lt;P&gt;Application: &lt;BR&gt;Electrical power industry &lt;BR&gt;Chemical engineering industry&lt;BR&gt;Textile industry&lt;BR&gt;Cement industry&lt;BR&gt;Waste incineration plant&lt;BR&gt;Heating boiler&lt;/P&gt; &lt;P&gt;FEATURES: &lt;BR&gt;1. Simple and cabinet structure. &lt;BR&gt;2. Single evaporator and two channels, concurrent processing two channels sample gases. &lt;BR&gt;3. Large volume sample gases processing. &lt;BR&gt;4. Automatic regulation, Constant temperature refrigeration. &lt;BR&gt;5. Easy maintenance and simple operation. &lt;BR&gt;6. Invalidation warning.&lt;/P&gt;2009-7-2 14:27:24<![CDATA[Multi-Gas Analyzer (MGA-3000)]]>http://www.tradevv.com/chinasuppliers/bcc2000/products-detail/china-Multi-Gas-Analyzer-MGA-3000-60ec6.html]]>The MGA-3000 Multi-Gas Analyzer adopts international advanced Non Dispersive Infrared&lt;BR&gt;Absorption technology. The greatest features are: &lt;BR&gt;1. High-precision, high sensitivity; &lt;BR&gt;2. With functions of Temperature, Pressure and Non-linearity compensations; &lt;BR&gt;3. The biggest measurement range of choices; &lt;BR&gt;4. Good stability, small drift.2009-7-2 15:28:01<![CDATA[Sell Dust and Particulate Monitor(KSP-I-1000D)]]>http://www.tradevv.com/chinasuppliers/bcc2000/offers-detail-60d9b/Sell-Dust-and-Particulate-Monitor-KSP-I-1000D.html]]>&lt;P&gt;Specification: &lt;BR&gt;Operating range: 0-12m&lt;BR&gt;Measuring range: 0.001~9999mg/m3&lt;BR&gt;Weight (each): 3kg&lt;BR&gt;Zero Drift: 0&lt;BR&gt;Full Span Drift: 0&lt;BR&gt;Response time: &amp;lt;1sec&lt;BR&gt;Outputs Signal: 4-20mA/0-10V&lt;/P&gt; &lt;P&gt;Features: &lt;BR&gt;1. Using the dynamic measuring principle to increase the precision of test result. &lt;BR&gt;2. In built flexibility, the concentration of particulate to be monitored feeds back to intelligent control equipment or data recording equipment through the analog output of 4-20mA or 0-10V. &lt;BR&gt;3. Unique system of protective gas to ensure clean surface probe. &lt;BR&gt;4. Apply to the electricity, metallurgy, cement, high-temperature incineration industries fever.&lt;/P&gt; &lt;P&gt;&amp;nbsp;&lt;/P&gt;2009-9-7 10:48:42<![CDATA[Sell FT-IR System]]>http://www.tradevv.com/chinasuppliers/bcc2000/offers-detail-60e70/Sell-FT-IR-System.html]]>Beijing Care Corporation Ltd is a leading manufacturer of FT-IR system configured with high quality spectrometer and detector. The gas cell with 10 meter optical length is designed by BCC, the LOD could reach high ppb level. The product has a competitive price with reliable performance. Fourier Transform Infrared Spectroscopy (FTIR) can be widely used. It is a powerful tool for identifying types of chemical bonds in a molecule by producing an infrared absorption spectrum like a molecular &quot;fingerprint&quot;. FTIR is most useful for identifying chemicals, organic or inorganic, it can be used to quantitate some components of an unknown mixture and it can also be applied to the analysis of solids, liquids, and gasses. The term Fourier Transform Infrared Spectroscopy (FTIR) refers to a fairly recent development in the manner in which the data is collected and converted from an interference pattern to a spectrum. Today's computerization of FTIR makes them faster and more sensitive than the older dispersive instruments.2009-9-7 10:48:42<![CDATA[Sell On-Line Triad Monitor of Temperature, Pressure and Flow Velocity (KPV-2000)]]>http://www.tradevv.com/chinasuppliers/bcc2000/offers-detail-60ea6/Sell-On-Line-Triad-Monitor-of-Temperature-Pressure-and-Flow-Velocity-KPV-2000.html]]>&lt;P&gt;The model KPV-2000 is an on-line triad monitor of temperature, pressure and flow velocity. &lt;/P&gt; &lt;P&gt;The features&lt;BR&gt;1. With long life working time; 2. Ease to maintain and low cost; &lt;BR&gt;3. With high measuring precision; 4. Proof against high temperature &lt;BR&gt;5. Automatically purify function&lt;/P&gt; &lt;P&gt;Temperature: &lt;BR&gt;Power requirements(KVA)&amp;lt;0.04KVA &lt;BR&gt;Outputs signal: 4-20mA&lt;BR&gt;Response time: ≤20s&lt;/P&gt; &lt;P&gt;Pressure: &lt;BR&gt;Measuring range: &lt;BR&gt;-4KPa~4KPa(differential pressure)&lt;BR&gt;Power requirements(KVA)&amp;lt;0.04KVA&lt;BR&gt;Outputs signal: 4-20mA&lt;BR&gt;Response time: ≤20s&lt;/P&gt; &lt;P&gt;Flow velocity: &lt;BR&gt;Measuring range: 3m/s ~ 40m/s&lt;BR&gt;Power requirements(KVA)&amp;lt;0.04KVA&lt;BR&gt;Outputs signal: 4-20mA&lt;BR&gt;Response time: ≤20s&lt;BR&gt;Resolving Power: 0.1m/s&lt;/P&gt;2009-9-7 10:48:42<![CDATA[Dust and Particulate Monitor(KSP-I-1000D)]]>http://www.tradevv.com/chinasuppliers/bcc2000/products-detail/china-Dust-and-Particulate-Monitor-KSP-I-1000D-60d9a.html]]>&lt;P&gt;Specification: &lt;BR&gt;Operating range: 0-12m&lt;BR&gt;Measuring range: 0.001~9999mg/m3&lt;BR&gt;Weight (each): 3kg&lt;BR&gt;Zero Drift: 0&lt;BR&gt;Full Span Drift: 0&lt;BR&gt;Response time: &amp;lt;1sec&lt;BR&gt;Outputs Signal: 4-20mA/0-10V&lt;/P&gt; &lt;P&gt;Features: &lt;BR&gt;1. Using the dynamic measuring principle to increase the precision of test result. &lt;BR&gt;2. In built flexibility, the concentration of particulate to be monitored feeds back to intelligent control equipment or data recording equipment through the analog output of 4-20mA or 0-10V. &lt;BR&gt;3. Unique system of protective gas to ensure clean surface probe. &lt;BR&gt;4. Apply to the electricity, metallurgy, cement, high-temperature incineration industries fever.&lt;/P&gt; &lt;P&gt;&amp;nbsp;&lt;/P&gt;2009-7-2 14:16:37<![CDATA[FT-IR System]]>http://www.tradevv.com/chinasuppliers/bcc2000/products-detail/china-FT-IR-System-60e6f.html]]>Beijing Care Corporation Ltd is a leading manufacturer of FT-IR system configured with high quality spectrometer and detector. The gas cell with 10 meter optical length is designed by BCC, the LOD could reach high ppb level. The product has a competitive price with reliable performance. Fourier Transform Infrared Spectroscopy (FTIR) can be widely used. It is a powerful tool for identifying types of chemical bonds in a molecule by producing an infrared absorption spectrum like a molecular &quot;fingerprint&quot;. FTIR is most useful for identifying chemicals, organic or inorganic, it can be used to quantitate some components of an unknown mixture and it can also be applied to the analysis of solids, liquids, and gasses. The term Fourier Transform Infrared Spectroscopy (FTIR) refers to a fairly recent development in the manner in which the data is collected and converted from an interference pattern to a spectrum. Today's computerization of FTIR makes them faster and more sensitive than the older dispersive instruments.2009-7-2 15:12:07<![CDATA[On-Line Triad Monitor of Temperature, Pressure and Flow Velocity (KPV-2000)]]>http://www.tradevv.com/chinasuppliers/bcc2000/products-detail/china-On-Line-Triad-Monitor-of-Temperature-Pressure-and-Flow-Velocity-KPV-2000-60ea5.html]]>&lt;P&gt;The model KPV-2000 is an on-line triad monitor of temperature, pressure and flow velocity. &lt;/P&gt; &lt;P&gt;The features&lt;BR&gt;1. With long life working time; 2. Ease to maintain and low cost; &lt;BR&gt;3. With high measuring precision; 4. Proof against high temperature &lt;BR&gt;5. Automatically purify function&lt;/P&gt; &lt;P&gt;Temperature: &lt;BR&gt;Power requirements(KVA)&amp;lt;0.04KVA &lt;BR&gt;Outputs signal: 4-20mA&lt;BR&gt;Response time: ≤20s&lt;/P&gt; &lt;P&gt;Pressure: &lt;BR&gt;Measuring range: &lt;BR&gt;-4KPa~4KPa(differential pressure)&lt;BR&gt;Power requirements(KVA)&amp;lt;0.04KVA&lt;BR&gt;Outputs signal: 4-20mA&lt;BR&gt;Response time: ≤20s&lt;/P&gt; &lt;P&gt;Flow velocity: &lt;BR&gt;Measuring range: 3m/s ~ 40m/s&lt;BR&gt;Power requirements(KVA)&amp;lt;0.04KVA&lt;BR&gt;Outputs signal: 4-20mA&lt;BR&gt;Response time: ≤20s&lt;BR&gt;Resolving Power: 0.1m/s&lt;/P&gt;2009-7-2 15:22:46<![CDATA[Sell Gas Probe (GSP-3000)]]>http://www.tradevv.com/chinasuppliers/bcc2000/offers-detail-60e3e/Sell-Gas-Probe-GSP-3000.html]]>&lt;P&gt;The model GSP-3000 Heated Gas Sample Probe is applicable to continuous extractive sampling system with the sample gas of high temperature, high dust and high humidity. The GSP-3000 Heated Gas Sample Probe is especially suited for sampling in continuous emission monitoring system (CEMS). &lt;/P&gt; &lt;P&gt;The GSP-3000 Gas Probe's unique design makes easy installation, reliable performance and convenient maintenance. GSP-3000 Gas Probe could adopt multiple suitable sample pipe and pre-filter for use. Filter (ceramic is standard) have immense filtering area and capacity. The filter can be conveniently replaced without any tools and needn't dismantle the sampling pipe or sampling line, so impurity was prevented into the sampling system. The gas sample probe could adjust the temperature of the whole filter chamber cause unique design of temperature controller and heater. &lt;/P&gt; &lt;P&gt;The GSP-3000 Gas Probe applies to continuous extractive sample gas from coal burning boiler and oil burning boiler. GSP-3000 Gas Probe is developed by BCC according to domestic user's demand, the equipment could run under all environment because it adopts anticorrosive and high temperature resistant materials. &lt;/P&gt; &lt;P&gt;Features: &lt;BR&gt;1. Have gas purge device, extension of maintenance cycle. &lt;BR&gt;2. Anticorrosive and high temperature resistant probe which could be used in various industries. &lt;BR&gt;3. Convenience disassembly and easy operation. &lt;BR&gt;4. Replacing filter element doesn't need any tools. &lt;BR&gt;5. Defend grade is IP65, appropriate for outdoor installation.&lt;/P&gt;2009-9-7 10:48:42<![CDATA[Gas Probe (GSP-3000)]]>http://www.tradevv.com/chinasuppliers/bcc2000/products-detail/china-Gas-Probe-GSP-3000-60e3d.html]]>&lt;P&gt;The model GSP-3000 Heated Gas Sample Probe is applicable to continuous extractive sampling system with the sample gas of high temperature, high dust and high humidity. The GSP-3000 Heated Gas Sample Probe is especially suited for sampling in continuous emission monitoring system (CEMS). &lt;/P&gt; &lt;P&gt;The GSP-3000 Gas Probe's unique design makes easy installation, reliable performance and convenient maintenance. GSP-3000 Gas Probe could adopt multiple suitable sample pipe and pre-filter for use. Filter (ceramic is standard) have immense filtering area and capacity. The filter can be conveniently replaced without any tools and needn't dismantle the sampling pipe or sampling line, so impurity was prevented into the sampling system. The gas sample probe could adjust the temperature of the whole filter chamber cause unique design of temperature controller and heater. &lt;/P&gt; &lt;P&gt;The GSP-3000 Gas Probe applies to continuous extractive sample gas from coal burning boiler and oil burning boiler. GSP-3000 Gas Probe is developed by BCC according to domestic user's demand, the equipment could run under all environment because it adopts anticorrosive and high temperature resistant materials. &lt;/P&gt; &lt;P&gt;Features: &lt;BR&gt;1. Have gas purge device, extension of maintenance cycle. &lt;BR&gt;2. Anticorrosive and high temperature resistant probe which could be used in various industries. &lt;BR&gt;3. Convenience disassembly and easy operation. &lt;BR&gt;4. Replacing filter element doesn't need any tools. &lt;BR&gt;5. Defend grade is IP65, appropriate for outdoor installation.&lt;/P&gt;2009-7-2 14:58:50