group nameHydraulic control valve
Min Order1 piece
brand nameGARLOS
modelY110X
payment method
update timeWed, 14 Jun 2017 10:38:32 GMT
Nominal Pressure 1.0/1.6MPa
Shell Test Pressure 1.5/2.4MPa
Seal Test Pressure 1.0/1.6MPa
Suitable Medium Water
Medium Temperature 0-80℃
Exit Pressure Range 0.2-0.8/ 0.2-1.2 MPa
Leakage 0
Pressure Adjust Error ±10%/ ±12%
Dynamic-static Pressure Difference ≤0.08/≤0.12
Min Order1 piece
Brief Introduction
Y110X Adjustable Pressure Reducing Sustaining Valve is a direct acting type film spring pressure reducing valve. Mainly composed of spring, film, piston, valve seat, disc, etc. Film senses downstream pressure directly to drive disc, to control open degree of disc to reduce or sustain pressure. Suitable for water, air, non corrosive liquid of working temperature of 0-80℃. In high rise building cold-hot water supply system and fire fighting water supply system, it can replace regular partition pipe, to simplify and save device, low project cost.
Parameters
Y110X/Y416X | Y110X/Y416X | |
Nominal Pressure | 1.0MPa | 1.6Pa |
Shell Test Pressure | 1.5MPa | 2.4MPa |
Seal Test Pressure | 1.0MPa | 1.6MPa |
Max Inlet Pressure | 1.0MPa | 1.6MPa |
Outlet Pressure Range | 0.2-0.8MPa | 0.2-1.2MPa |
Dynamic-static Pressure Difference | ≤0.08MPa | ≤0.12MPa |
Valve Adjusting Error Range | ±10% | ±12% |
Leakage | 0 | |
Working Temperature | 0℃-80℃ |
Installation
Dimension
With Meter
DN | 15 | 20 | 25 | 32 | 40 | 50 |
L | 95 | 100 | 108 | 137 | 158 | 178 |
H | 118 | 126 | 142 | 162 | 178 | 195 |
Without Meter
DN | 15 | 20 | 25 | 32 | 40 | 50 |
L | 76 | 80 | 88 | 112 | 118 | 145 |
H | 95 | 100 | 108 | 137 | 158 | 178 |