group nameReliable Test Chamber
Min Order1 piece
brand nameHUDA Test Machine Manufacturer
modelHUD-E808-90
payment methodL/C, D/A, D/P, T/T, Paypal
update timeThu, 07 Apr 2022 09:27:57 GMT
Internal Size (L×W×H) 600*450*400mm
Equipment Material Both inside & outside shell adopt P.V.C rigid plastic board
Temperature Range Room temperature ~ 55℃
Temperature Fluctuations ≤±0.5℃
Temperature Uniformity ≤±2℃
Temperature Precision ±1℃
Spraying method Continuous and Periodic spray type
Test Chamber Temperature Salt Spray Method (NSS ACSS)35±1℃
Brine Temperature 35℃±1℃
Min Order1 piece
Application
The salt spray test chamber is mainly suitable for the surface treatment of various materials, including coatings, electroplating, organic and inorganic coatings, extreme treatments, anti-rust oils and other anti-corrosion treatments to test the corrosion resistance of their products.
Features
1. Durable 8 mm PVC construction, anti-corrosion and easy to clean.
2. Reservoirs with mixing system on stand.
3. Separate heating system apart from salt testing chamber to ensure accurate result and protect circuit.
4. Exposure zone lined with corrosion-resistant PVC sheets.
5. Clear cover allows viewing of test conditions.
6. Peaked cover prevents dripping of condensation onto samples.
7. Water seal and water level protection system.
8. Heated humidifying tower with air relief valve, adjustable tower tip to orient salt fog.
9. Automatic DI water fills to humidifying tower.
10. Digital temperature control.
11. Integral over-protection on heaters.
12. Low water cut-off protection on humidifying tower.
Main Parameters
Internal Size (W*D*H) | 900*600*500mm |
External Size (W*D*H) | 1410*880*1280mm |
Equipment Material | P.V.C rigid plastic plate, thickness 8mm |
Sample tray | Diameter 10mm glass fiber rod, anti-rust V-shape plastic steel to make sure sample in 15~30 degree inclined |
Temperature Range | Room temperature ~ 55℃ |
Temperature Fluctuations | ≤±0.5℃ |
Temperature Uniformity | ≤±2℃ |
Temperature Precision | ±1℃ |
Spraying method | Continuous and Periodic spray type |
Test Chamber Temperature | Salt Spray Method (NSS ACSS)35±1℃ |
Saturated air Barrel Temperature | Salt Spray Method (NSS ACSS)47±1℃ |
Brine Temperature | 35℃±1℃ |
Spray Quantity | 1.0~2.0 ml / 80cm2 / hr |
PH value | Salt Spray Method (NSS ACSS6.5~7.2) |
Lab Volume | 270L |
Brine Tank Capacity | 25L |
Multiple Safety Protection Devices | Current discharge protection, over pressure protection, over temperature protection, over load fuse protection |
Accessories | Testing Salt/ Measuring tank/Nozzle Equipment x 1 set |
Internal Size (W*D*H) | 900*600*500mm |
Test criteria | ASTM B117-08, ISO 9227 |
6YRS haiyouda
网络文化经营许可证:浙ICP备14006100号-11 2007-2024 Tradevv.com. All rights reserved.