Remote sensing length infrared laser safety light curtain sensor safety light barrier

  • group nameCAT remote sensing safety light curtain sensor

  • Min Order1 piece

  • brand nameCYNDAR

  • modelCAT

  • payment methodT/T, PayPal

  • update timeSun, 21 Feb 2021 16:23:57 GMT

Paramtents

  • Light curtain form Opposite

  • light source Modulated infrared LED

  • Detection distance 30~3000mm, 30~6000mm, 30~30000mm

Packging & Delivery

  • Min Order1 piece

Briefing

The formula for calculating the protection height of safety light curtain is: number of optical axes-1) * optical axis spacing.

Detailed

CAT Specification Sheet
Product features

When choosing a light curtain safety device model, there are several parameters needed, so how do you distinguish the protection height and the protection distance when choosing the safety light curtain sensor?

The formula for calculating the protection height is: (number of optical axes-1) * optical axis spacing. The protection distance refers to the distance between the light curtain transmitter and the receiver, which is also called the distance of the beam.

What is the role of the projector in the laser curtain sensor?

Light curtain sensor is also known as light curtain safety device (also known as infrared safety light curtain, punch protector, infrared safety protection device, etc.). In modern factories, humans and machines work together on some potentially dangerous mechanical equipment, such as Stamping machinery, shearing equipment, metal cutting equipment, automated assembly lines, automated welding lines, mechanical transmission and handling equipment, and hazardous areas (toxic, high pressure, high temperature, etc.) are likely to cause personal injury to operators.

Light curtain form

Opposite

Optical axis spacing

10mm

14mm

20mm

25mm

30mm

40mm

Detection accuracy

18mm

22mm

28mm

33mm

38mm

48mm

Number of beams

6、8…32

6、8…32

4、6…32

6、8…32

4、6…32

4、6…32

Protection height

Optical axis spacing × (number of beams-1)

Detection distance

30~3000mm, 30~6000mm, 30~30000mm

Dimensions

35×51×Lmm (L is the length of the emitter/receiver)

voltage

DC12/24V AC110-220V (with controller, relay passive output)

Current consumption

≤200mA

Output

NPN/PNP type, sink current 500mA, voltage drop below 1.5V, polarity, short circuit, overload protection

Connection method

Circular aviation socket with special link cable, 5 cores for emitter and 5 cores for receiver

light source

Modulated infrared LED

Shell material

Aluminum alloy, end cover: ABS reinforced nylon

 

 

Component
Data line
Mounting brackets
Five core interface
Swivel arm (aluminum alloy)
Shape
Wiring diagram

Application:

Ir light curtain is widely used in presses, hydraulic presses, hydraulic presses, shears, automatic doors and other large machinery or dangerous situations requiring long-distance protection.

20mm optical axis spacing is generally used to protect the palm. When the distance is relatively close to the dangerous area, the possibility of danger cannot be ignored. If the remote sensing length infrared laser safety light curtain sensor safety light barrier is used to protect the palm, Then the optical axis spacing of 20mm is sufficient, such as the safety protection of personnel on the shearing machine.