group nameDual FOV Infrared Lens
Min Order1 piece
brand nameQuanhom Optronics
modelGLD25N100
payment methodT/T, D/P D/A, PayPal, Westem Union
update timeFri, 08 Nov 2024 06:45:18 GMT
LWIR Lens 25/100mm f0.85/1.0
Applications Security and Surveillance
Mechanical Interface Thread
Min Order1 piece
HFOV
|
160x120
|
320x240
|
336x256 | 384x288 | 640x480 | 640x512 | 1024x768 |
1280x1024
|
25μm | 2.3°/9.1° | 4.6°/18.2° | 4.8°/19.1° | 5.5°/21.7° | / | / | / | / |
17μm
|
1.6°/6.2°
|
3.1°/12.4°
|
3.3°/13.0° | 3.7°/14.9° | 6.2°/24.6° | 6.2°/24.6° | / |
/
|
12μm
|
1.1°/4.4°
|
2.2°/8.8°
|
3.2°/9.2° | 2.6°/10.5° | 4.4°/17.5° | 4.4°/17.5° | / |
/
|
Optical |
|||
Focal Length[mm]
|
25/100
|
||
F/#
|
0.85/1.0
|
||
Wave Length | 8-14μm | ||
Detector | 640x512,17μm | ||
Focus Range | 5m-Infinity |
Mechanical |
|||
|
Motorized Dual Vision
|
||
|
|
||
Weight
|
|
Environmental |
|||
Operating Temperature
|
-40℃ to +60℃
|
||
Storage Temperature | -50℃ to +80℃ | ||
External Coating
|
DLC
|
||
Sealing | IP67 |
file name
|
type |
download
|
||
PDF |
1. During the focusing process, there is a large moving target in the lens screen (occupying more than 1/3 of the picture), can be refocused;
2.If the lens is used for a long time, the gear, CAM and other transmission parts wear and tear, resulting in unclear focus, the module or control board parameters can be adjusted to make the focus clear again;
3. Hardware problems, such as potentiometer does not work, replace the hardware that does not work.
1. Replace the USB port, which may be incompatible with the data cable;
2.Replace the data cable,maybe the data cable is not compatible with the computer or the cable data is wrongly selected;
3. Confirm the wiring of the module or the control board, maybe the wiring is loose;
4.Module or control board hardware problem, replace the hardware.
A. Structurally, a continuous zoom lens has two sets of adjustable lenses, which are used to adjust the focus and sharpness respectively. The dual-field lens has only one set of adjustable lenses, which is used to switch focal length and adjusts the sharpness of the picture.
B. In General, continuous zoom lenses require two sets of motors to control. Dual-field lenses require only one set of motors to switch the focal length and adjust sharpness.
C. The focal length of continuous zoom lenses can be any value within the design range. Whereas the focal length of dual-field lenses can only be switched between the two fixed focal length.