MWIR for Cooled Camera 15-300mm f/4.0

  • group nameMedium Wave Infrared (MWIR) Lens

  • Min Order1 piece

  • brand nameQuanhom Optronics

  • modelGMZ30040UA6415-E01

  • payment methodT/T, D/P D/A, PayPal, Westem Union

  • update timeFri, 08 Nov 2024 15:08:59 GMT

Paramtents

  • LWIR Lens 15-300mm f/4.0

  • Applications Security and Surveillance

  • Focus Mechanism Motorized

Packging & Delivery

  • Min Order1 piece

Briefing

Infrared Zoom Lens,can be applied to Homeland Security.

Detailed

  • Specifications
  • Download file
  • FAQ
  • Video
  • Applications
Specifications
HFOV
160x120
320x240
336x256
384x288
640x480
640x512
1024x768
1280x1024
15μm
0.4°-9.1°
0.8°-18.2°
0.9°-19.1°
1.0°-21.7°
1.7°-35.5°
1.7°-35.5°
/
/

Optical

Focal Length[mm]
15-300
F/#
4.0
NETD
≤40mk

Wavelength

3.7-4.8μm

Interface and Function

Frame Frequency
30Hz
Video Output
HD-SDI (1080P;30Hz)
Camera control
RS422
Shutter Correction
Manual/Automatic
Optical Axis Tolerance
≤4Pixel
Background Correction
Y
Polarity Control
Black Hot/White Hot
Digital Zoom
x2/x4
Cross Display
On/Off
Cross Location/Gain/Brightness/Enhancement
AdjustableVertical/Horizontal
Image Flip
Vertical/Horizontal
Power
DC 28 ±1V
Power comsumption
≤10W@25℃

Physical Parameter

Weight

≤2600g

Dimensions(mm)
176.5x125x105.2

Environmental

Operating Temperature
-40℃ to +60
Storage Temperature
-55℃ to +65
External Coating
AR
Front Element Sealing
IP67
Download document
FAQ
- Why the Infrared Zoom Athermalized Lens autofocus is not clear?

There are many reasons why the lens autofocus is not clear, the main reasons are as follows which can be checked one by one:

1. During the focusing process, there is a large moving target in the lens screen (occupying more than 1/3 of the picture), which can be refocused;

2. If the lens is used for a long time, the gear, CAM and other transmission parts wear and tear, resulting in unclear focus, the module or control board parameters can be adjusted to make the focus clear again;

3. Hardware problems, such as the potentiometer does not work, replace the hardware that does not work.

- Why cannot the lens control board or module connect to the computer?

There are many reasons why the lens control board and the computer cannot be connected, the main reasons are as follows which can be checked one by one:

1. Replace the USB port, which may be incompatible with the data cable;

2. Replace the data cable, maybe the data cable is not compatible with the computer or the cable data is wrongly selected;

3. Confirm the wiring of the module or the control board, maybe the wiring is loose;

4. Module or control board hardware problem, replace the hardware.

APPLICATIONS
Homeland Security
Maritime & Naval
Security & Surveillance
Nearest port for product export
Shanghai, Ningbo, Tianjin, Khorgos
Delivery clauses under the trade mode
FOB, CFR, CIF, EXW, CIP, FCA, CPT, DDP, DDU, Express Delivery, DAF, DES
Acceptable payment methods
T/T, D/P D/A, PayPal, Westem Union
Contact Suppliers

Follow this Suppliers