group nameLWIR Thermal Camera Module
Min Order1 piece
brand nameQuanhom Optronics
modelITZ1212
payment methodT/T, D/P D/A, PayPal, Westem Union
update timeTue, 05 Nov 2024 02:36:43 GMT
Detector Type Uncooled focal plane
Pixel Pitch 12μm
Resolution 1280x1024
Size 45x45x36.2mm
Digital video output SDI
Min Order1 piece
Detector characteristic |
|||
Detector type | Uncooled focal plane | ||
Resolution
|
1280*1024
|
||
Pitch Size
|
12μm
|
||
Spectral Range
|
8-14μm
|
||
Image Frequency | 30Hz | ||
NETD | ≤50mK or ≤40mK (F/1,25Hz,300K) | ||
Video Output | Digital: SDI | ||
Power Supply | DC 12V | ||
Power Consumption | ≤5W | ||
Size(LxWxH) | ≤45x45x36.2(mm) | ||
Operating Temperature | -40℃ to +50℃ | ||
Storage Temperature | -45℃ to +85℃ |
file name
|
type |
download
|
||
PDF |
1. During the focusing process, there is a large moving target in the lens screen (occupying more than 1/3 of the picture), which can be refocused;
2. If the lens is used for a long time, the gear, CAM and other transmission parts wear and tear, resulting in unclear focus, the module or control board parameters can be adjusted to make the focus clear again;
3. Hardware problems, such as the potentiometer does not work, replace the hardware that does not work.
1. Replace the USB port, which may be incompatible with the data cable;
2. Replace the data cable,maybe the data cable is not compatible with the computer or the cable data is wrongly selected;
3. Confirm the wiring of the module or the control board, maybe the wiring is loose;
4. Module or control board hardware problem, replace the hardware.