group nameIndustrial Dehumidifier
Min Order1 unit
brand nameEast Dehumidifier OEM ODM Manufacturing
modelSDI-168L
payment methodWestern Union, MoneyGram, T/T, Paypal
update timeFri, 08 Nov 2024 07:55:26 GMT
Installation Universal wheel / Floor standing
Dehumidifying Type Refrigeration
Refrigeration Technology Compressor
Compressor Type Rotary
Refrigerant R410a / R407c
Cooling Capacity 8.2 Kw
Brand Name East Dehumidifier OEM ODM Manufacturing
Location Zhejiang, China
Condition Brand New
Size120cm x 138cm x 85cm
Weight250.00kg / unit
Min Order1 unit
EAST industrial dehumidifiers are designed for industry space bigger than 500 cube meters. Quality metal plate with CNC machine cutting, and painted with anti-corrosion paint, solid and long working life. The units use heavy industry quality Panasonic compressor and thickened inner grooved copper pipe to reach the best efficient of dehumidifying. High accuracy humidity sensor from Shinyei Japan has the feature of high anti-interference to make the units working more accurate. The intelligent control system has the function of malfunction self-inspection, automatic power off, continuous working and safety protection. Humidity control range 45%~99% RH. Water removal capacity up to 1000 liters per day
Model no.
|
SDI-168L
|
|
Cooling Capacity | 28,000 BTU | 5.3 KW |
Water Removal Capacity @86℉, RH80%, 24hrs | 350 Pints | 168L |
Supply Voltage | North America: 440~480v/60hz three phase Europe and China: 380~400v/50hz | |
Rated Power | 2820W | |
Rated Amps
|
5.5A
|
|
Air Volume @ 0.0" ,CFM
|
1000
|
1800m³/h
|
Working Temperature
|
41℉~100℉
|
5℃~38℃
|
Humidity Range (RH) | 40%~95% | |
Net Dimensions | 23.4" x 16" x 63.2" | 595x405x1605mm |
Packed Dimesions | 26.6" x 19.2" x 71" | 695x505x1705mm |
Net Weight | 198 Lbs | 90Kg |
Gross Weight | 230 Lbs | 100Kg |
Noise | ≤60dB | |
Applying Area | 1,200~2,200 Sqft | 120-220㎡ |
World-famous brand compressor
High pressure refrigerant liquid enters into the evaporator after throttling by capillary. The refrigerant is evaporated as low temperature and low pressure gas by absorbing thermal from air after heat exchange. The low temperature low pressure refrigerant gas is inhaled into the compressor, after compressor compressing, the gas become high temperature high pressure refrigerant gas and get into the condenser. Then the refrigerant gas get into the condenser, after heat dissipation, the refrigerant gas become high pressure refrigerant liquid. Above is a complete cycle of refrigerating after repeating.
网络文化经营许可证:浙ICP备14006100号-11 2007-2024 Tradevv.com. All rights reserved.