Portable Aed First-Aid Automated External Defibrillator for Patient

  • group nameDefibrillator

  • Min Order1 piece

  • modelCNME011309

  • payment methodL/C, D/A, D/P, Western Union, MoneyGram, T/T, Paypal

  • update timeWed, 28 Jul 2021 16:31:31 GMT

Paramtents

  • Classification Physiological Functions of Diagnosis and Monitorin

  • Type Defibrillator

  • Certification CE

  • Product Name Portable Aed

  • Output Biphasic

  • Max Energy 200j

Packging & Delivery

  • Min Order1 piece

Briefing

Portable Aed First-Aid Automated External Defibrillator for Patient ,Extensive voice and visual prompts for the operator.

Detailed

Portable Aed First-Aid Automated External Defibrillator for Patient

Basic Info.
Model NO.
CNME011309
Analysis Time
9 Sec
Display
Color LCD Screen
Origin
China
Portable AED First-aid Automated External Defibrillator for Patient

Product features:
1.Three-step defibrillation process.
2.Two-button operation.
3.Extensive voice and visual prompts for the operator.
4.Biphasic energy output.
5.Lock-out protection to prevent inadvertent defibrillation.
6.Continuous event recording for reporting each use to a printer or computer.
7.Weekly self-test to ensure readiness.
8.Color LCD screen
9.screen for ECG wave and settings.
10.Adult and Pediatric defibrillation.
11.Multi language voice and monitor.
12.SD Card for recording capacity.
13.Infra-red for data transfer.
14.Multi language.
15.LCD Battery Capacity Indicator.
16.CPR coaching (Optional).
17.ECG measurement by 3 lead cable (Optional).
Technical Specification:
Output
Biphasic Truncated exponential
Energy Sequence(adult)
50/150/200(Default)
150/200/200
200/200/200
Note: the Energy sequence can be changed using the computer IR port.
Energy Sequence(Pediatric)
50/70/85(Default)
70/70/85
70/85/85
85/85/85
Note: the Energy sequence can be changed using the computer IR port.
Charge Time
10 sec. to 200 J
Analysis Time
9 sec.
The maximum time from the initiation of rhythm analysis to readiness for maximum Energy discharge after 15 shocks
Less than 30 seconds
The maximum time from initially switching power on to readiness for maximum Energy discharge after 15 shocks.
Less than 35seconds
Audible Prompts
19 audible prompts
Visual 
Prompts LED/LCD
Controls
six buttons - On/Off, Shock, and 4 software-configurable buttons
Output Energy Accuracy
±15% into any impedance from 25 to 175Ω
The Maximum Voltage
1800±20V
Output disabled when the PATIENT impedance is outside limits
20Ω to 200Ω
Recovery of the ECG input after defibrillation
<10s
AED Storage Software (Option):
Its used to assist upper supervisory system of Automatic External Defibrillator DEFI and support transmission of storage data from lower control system of DEFI. It is used for event documentation, display of real-time ECG, voice prompts waveform, display of voice prompts and print of selected wave-forms.
Details: