FCJ GYXTW Outdoor Central Tube Communication Optic Cable

  • group nameDirect Burial Fiber Optic Cables

  • Min Order1 kilometer

  • brand nameFCJ Fiber Optic Products Manufacturer

  • modelGYXTW

  • payment methodL/C, D/A, D/P, Western Union, T/T, Paypal

  • update timeThu, 07 Nov 2024 23:47:38 GMT

Paramtents

  • Number of Conductors ≥ 10

  • Fiber Type G652D/Multimode

  • Armored Yes

  • Operating Temperature -40°C to + 70°C

  • Installation Aerial/Direct Buried/Duct

  • Transport Package Wooden Drums or as Per Customers′ Requests

Packging & Delivery

  • Min Order1 kilometer

Briefing

The fibers, 250μm, are positioned in a loose tube made of a high modulus plastic.

Detailed

Description

The fibers, 250μm, are positioned in a loose tube made of a high modulus plastic. The tubes are filled with a water-resistant filling compound. A steel wire, sometimes sheathed with polyethylene (PE) for cable with high fiber count, locates in the center of core as a metallic strength member. Tubes (and fillers) are stranded around the strength member into a compact and circular cable core. The cable core is filled with the filling compound to protect it from water ingress, over which a thin PE inner sheath is applied. After the PSP is longitudinally applied over the inner sheath, the cable is completed with a PE outer sheath.

Characteristics

· Good mechanical and temperature performance

· High strength looes tube that is hydrolysis resistant

· Special tube filling compound ensure a critical protection of fiber

· Crush resistance and flexibility

· The following measures are taken to ensure the cable watertight:

                - Steel wire used as the central strength member

                - Loose tube filling compound

                - 100% cable core filling

                - PSP enhancing moisture-proof

                - Water-blocking material

Standards

GYTY53 cable complies with Standard YD/T 901-2001as well as IEC 60794-1.

Optical Characteristics

G.652

G.655

50/125μm

62.5/125μm

Attenuation
(+20℃)

@850nm

≤3.0 dB/km

≤3.0 dB/km

@1300nm

≤1.0 dB/km

≤1.0 dB/km

@1310nm

≤0.36 dB/km

≤0.40 dB/km

@1550nm

≤0.22 dB/km

≤0.23dB/km

Bandwidth

(Class A)

@850nm

≥500 MHz·km

≥200 MHz·km

@1300nm

≥1000 MHz·km

≥600 MHz·km

Numerical Aperture

0.200±0.015NA

0.275±0.015NA

Cable Cut-off Wavelength

≤1260nm

≤1480nm

Technical Parameters

Cable Type

Fiber Count

Cable Diameter
mm

Cable Weight kg/km

Tensile Strength
Long/Short Term N

Crush Resistance
Long/Short Term N/100mm

Bending Radius
Static/Dynamic
mm

GYXS/GYXTW-2~12

2~12

10.0

105

600/1500

300/1000

10D/20D

GYXS/GYXTW-2~12

2~12

10.6

124

1000/3000

1000/3000

10D/20D

GYXS/GYXTW-14~24

14~24

12.5

149

1000/3000

1000/3000

10D/20D

GYXS/GYXTW-26~36

26~36

14.0

190

1000/3000

1000/3000

10D/20D

GYXS/GYXTW-38~48

38~48
15.0
216
1000/3000
1000/3000
10D/20D

Storage/Operating Temperature : -40℃ to + 70℃