group nameSmall Scale Methanol Plant For Laboratory Multi Bioreactor Pressure Fermentation
Min Order1 piece
brand nameBAILUN bio Bioreactor and Fermenter Manufacturer
modelBLBIO-GJAV
payment methodL/C, D/A, D/P, Western Union
update timeTue, 05 Nov 2024 05:40:06 GMT
Weight 300KG
Warranty 1 Year
Machinery Capacity 50L-50000L
Machinery Test Report Provided
Warranty of core components 1 year
Core Components Gearbox, Motor, Gear, Pump, Pressure vessel, PLC,
Key Selling Points Automatic
Marketing Type New Product 2024
Video outgoing-inspection Provided
Processing Fermenting Equipment
Min Order1 piece
Parameter
|
Description
|
||
Total volume
|
5L,10L,15L,20L,30L,50L,100L,200L,500L,1000L, 5KL, 50KL, 200KL etc. |
||
Working volume
|
30%~70%
|
||
Tank
|
Jacket tank, made by SS316 and SS304, tank design pressure 0.3Mpa, jacket design pressure 0.35Mpa, polishing 0.4-0.6um, ratio of diameter and height is 1:2.2-2.5
|
Stirring system
|
Mechanical drive on the top/bottom or Magnetic drive on the top, 3pcs height adjustable six-blade paddle
Stir speed: 50~1000rpm/50-400rpm |
||
Sterilization
|
Sterilize in place(SIP), auto control by program
|
||
Clean
|
Clean in place (CIP) by spray ball
|
||
Gas control
|
Control by rotor meter, air flow 1 vvm
|
Feeding
|
Automatically feeding by peristaltic pump
|
||
Anti-foam control
|
Automatically add antifoam by peristaltic pump |
||
Temperature control
|
Auto-control, electric heating range: water source add 5℃ to 70℃
|
||
PH control
|
PH 2.00-12.00±0.1, auto-control adding acid/base by peristaltic pump, pH sensor from Hamilton/Mettler, Switzerland.
|
Do control
|
0-150±3% displaying precision 0.1%, DO sensor from Hamilton/Mettler, Switzerland. DO coupling with agitation, oxygen. |
||
Sampling
|
Sampling valve, can sterilization separately, manual
|
||
Harvest
|
Zero dead zone bottom valve(Gemu/Burket,Germany), can sterilization separately, manual/auto
|
||
Lid lift system
|
30L-500L have lid lift system, 700-1000L have human hole.
|
Innoculation | 4 valves group or pin in with flam protection | ||
Pressure
|
Auto control, BD Germany pressure transmitter or Lambert differential pressure liquid level gauge.
|
||
Exhaust
|
Have condenser before exhaust, control by diagram valve / Proportional control valve.
|
||
Control parameters
|
10in touch screen, Siemens PLC control system with control parameters (stirring, pH, DO, temperature, feeding, gas etc.), data analysis, data logging, data output and printing, overrun alarm, language switching and other functions
|
||
Optional configuration
|
O2/N2/CO2 gas control, Level sensor, OD sensor, Turbidity sensor, ORP sensor, Weight system, Live cell sensor etc.
|