DB-Y50 | Laser Detector Sensor | DADISICK

  • group nameDA-Y & DB-Y Series

  • Min Order1 piece

  • brand nameDADISICK

  • modelDA-Y & DB-Y Series | DB-Y50

  • update timeFri, 08 Nov 2024 07:47:26 GMT

Paramtents

  • Measuring frequency: 1Hz-40Hz

  • Communication interface: RS232/RS485 (switchable)

  • Laser type: Class II, 660±15nm, ≤1mW

  • Measuring distance 0.2-50m

  • Measurement resolution: 1mm

  • Power supply: DC15~30V

  • Power consumption: <3.0W

  • Protection grade: IP67

Packging & Delivery

  • Min Order1 piece

Briefing

Measuring frequency: 1Hz-40Hz
Communication interface: RS232/RS485 (switchable)
Measuring distance: 0.2-50m
Measurement resolution: 1mm

Detailed

DADISICK Laser Sensor Factory
DA-Y & DB-Y Series
Models comparison
Type A
Models
DA-Y10
DA-Y20
DA-Y30
DA-Y50
DA-Y100
Measuring range
0.2-10m
0.2-20m
0.2-30m
0.2-50m
0.2-100m
Output mode
Digital quantity & switch quantity
Type B
Models
DB-Y10
DB-Y20
DB-Y30
DB-Y50
DB-Y100
Measuring range
0.2-10m
0.2-20m
0.2-30m
0.2-50m
0.2-100m
Voltage/current output
Can be set to 0~5V / 0~10V / 4~20mA / 0~20mA /0~24mA output *Note 2
Voltage output error
0.2%+0.5mV
Current output error
0.2%+0.005mA
Output mode
Digital quantity, switch quantity, analog quantity
Specification
Communication interface
RS232/RS485 (switchable)
Measuring frequency
1Hz-40Hz
Laser type
Class II, 660±15nm, ≤1mW
Measurement resolution
1mm
Measurement error
±(2mm+d * one ten thousandth) *Note 1
Indicator light
Red laser
Spot size
@1m∅6mm; @10m∅8mm;
@20m∅12mm; @30m∅16mm;
Display
128x32 dot matrix screen
Backlight off time
30 minutes (can be set to normally on)
Operating mode
Off measurement, continuous measurement
Transistor switch output
2 channels (cannot exceed DC36V 0.5A) *Note 3
Power supply
DC15~30V
Power consumption
<3.0W
Protection grade
IP67
Shell material
Die-cast zinc alloy
Working temperature
-10°C~50°C
Storage temperature and humidity
-20°C~60°C, 20%~85%RH
Overheating protection
When the body temperature is higher than 70°C, the measurement will be shut down and when the temperature is lower than 70°C, the measurement will be resumed.
Dimension
88.45x40x59.3mm (including connection base)
Notes
*Note 1: When [Speed Level] is 1.
"d" represents the actual distance. In harsh environments, such as when the sun is too strong and the ambient temperature fluctuates too much, there will be a large error in the measurement results. In this case, the effect is better when used with a target reflector.
*Note 2: Current and voltage can' t be output at the same time.
*Note 3: If the external DC output of the transistor switch exceeds the limited voltage or current, it may cause permanent damage to the instrument.
DIMENSION                                                                                                                                                                                           
Laser displacement DA-Y & DB-Y series
WIRING DIAGRAM                                                                                                                                                                                    
RS485 Wiring Method
Laser measurement sensor DA-Y & DB-Y series cable description
RS232 Wiring Method
Laser sensor switch DA-Y & DB-Y series signal output selection
DOCUMENTS & DOWNLOADS                                                                                                                                                                  
CATALOGUE

DA-Y&DB-Y series laser displacement sensor