NAAKUU NKW1 Series Air Circuit Breaker ACB For Industrial Electrical

  • group nameAir Circuit Breaker

  • Min Order1 piece

  • brand nameNAAKUU Electrical Equipment Manufacturer

  • modelNKW1

  • payment methodT/T, L/C, MoneyGram, Credit Card, PayPal, Westem Union, Cash, Escrow

  • update timeWed, 13 Nov 2024 04:14:22 GMT

Paramtents

  • N Pole Rated Current(A):100%In Rated Operational Voltage:AC400V、AC690V

  • Rated Insulation Voltage:1000V Rated Frequency(Hz):50

  • Model:NKW1-2000、NKW1-3200、NKW1-4000、NKW1-6300 Pole:3、4

Packging & Delivery

  • Size100cm x 100cm x 110cm

  • Weight30.00kg / piece

  • Min Order1 piece

Briefing

NAAKUU NPW1 is an air circuit breaker ACB for Industrial Electrical.

Detailed

Product Introduction
NKW1 ACB


NKW1 series universal circuit breaker (also called Air Circuit Breaker/ACB) is suitable for electrical energy distribution and protection of circuit in the distribution network of AC 50Hz / 60Hz, rated current 400-6300A, rated insulation voltage AC1000V, rated working voltage AC400V, AC690V. It can protect electrical equipments from the hazards of overload, undervoltage, short circuit, single-phase grounding and other faults. At the same time, it has isolation function. The variety of protection functions of the circuit breaker can achieve high-precision selective protection, avoid unnecessary power outages, and improve power supply reliability and safety. NPK1-2000, 3000 (GH) live replaceable controller circuit breaker is a new structure circuit breaker newly developed by our company that can quickly replace the controller without opening the cabinet door or cutting the main circuit. The rated current is 400-3200A, which can meet the requirements of zero power outage. It is the first product at home and abroad and has a number of invention patents and utility model patent.

ACB
Product Detailed Parameters
Model
NKW1-2000
NKW1-3200
NKW1-4000
NKW1-6300
Rated Current (A)
400、630、800
1000/1250/1600
2000
1600、2000、2500
2900、3200
3200、3600、4000
4000、5000、6300
N Pole Rated Current(A)
100%In
100%In
100%In
100%In
Rated Operational Voltage(V)
AC400、AC690
Rated Frequency(Hz)
50
Rated Insulation Voltage(V)
1000
Rated Impulse Withstand Voltage (V)
12
Pole
3/4
Full Segmented Time(ms)
≤30
Close Time(ms)
≤60
Icu(kA)
AC400V
80
100
100
120
AC690V
65
65
65
85
Ics(kA)
AC400V
65
80
80
100
AC690V
50
65
65
75
Icm(kA)
AC400V
176
220
220
265
AC690V
110
143
143
176
Operational Performance
Electrical Life
AC400V
8000
3000
2000
1000
AC690V
5000
2000
1000
800
Mechanical Life
maintenance-free
15000
10000
8000
5000
with maintenance
20000
15000
15000
10000
Mounting Type
Fixed Type
Drawer Type
Main Circuit Wiring Method
Fixed Type
Horizantal Wiring、Vertical Wiring、L-shaped Wiring
Horizantal Wiring
Horizantal Wiring、Vertical Wiring、L-shaped Wiring
Horizantal Wiring、Vertical Wiring、L-shaped Wiring
Drawer Type
Horizantal Wiring、Vertical Wiring、L-shaped Wiring
Horizantal Wiring、Vertical Wiring
Horizantal Wiring、Vertical Wiring、L-shaped Wiring
Horizantal Wiring、Vertical Wiring、L-shaped Wiring
Size(mm)
Fixed 3P
400*362*327
400*422*327
Fixed 4P
400*457*327
400*537*327
Drawer 3P
450*375*421
450*435*421
450*500*421
450*813*486
450*928*496
Drawer 4P
450*470*421
450*550*421
450*788*486
450*928*486
450*928*486
Weight
Fixed 3P
41
42.4
44.5
48
59
Fixed 4P
53
55.1
57.8
61.6
76.7
Drawer 3P
65.4
68
69.8
75
90
93
230
230
Drawer 4P
63.9
87.8
92.3
95
117
210
240
240
Tip:▲Means it has this feature.
Our Feature:
1.
Operating mechanism 
The operating mechanism and manual, electric transmission mechanism are located on the front of the circuit breaker. The operating mechanism adopts a five bar free release mechanism, which is in the form of well energy. During use, the mechanism is in the pre energy position. As long as the circuit breaker receives a closing command, it can immediately close. The pre energy release can be completed using manual energy technology or combined magnetic technology. The Shendong motor mechanism is self-contained and can move through a concave convex groove between the shaft and the main shaft, making installation convenient.
2.
Tactile system
Adopting a one-stage contact system, at different parts of the same contact, the contact unit has both the main contact function and the arc contact function. New arc resistant materials are used to prevent the contact from distributing hot surfaces and causing high temperature after breaking the circuit breaker current. The contact system adopts multiple wells to reduce power and improve the stability of the contact.
3.
Arc chamber
Each pole has an arc chamber, which is used to isolate the electrodes, isolate them from each other, and isolate them from other parts of the circuit breaker and operators. All the arc chambers are placed inside the insulated base, increasing the mechanical strength of the arc chamber wall and preventing them from exploding when breaking large short-circuit currents.

Air Circuit Breaker
What can we do for you?
High Quality Service
High quality service

  • 1.Twenty years of experience in foreign trade,we have sufficient talent and resources in foreign trade exports , and have successively exported to overseas countries.

  • 2.OEM/ODM:Strong R&D and design team to meet different customization needs..

  • 3.After sale services: 2yrs warranty, product global liability insurance.

If the above model is not suitable for your workpiece, please tell us your need and then we can send you the most satisfying drawing.
contact us
Nearest port for product export
Ningbo Port, Shanghai Port, Guangzhou Port, Qingdao Port
Delivery clauses under the trade mode
FOB, CFR, CIF, EXW, FAS, CIP, FCA, CPT, DEQ, DDP, DDU, Express Delivery, DAF, DES
Acceptable payment methods
T/T, L/C, MoneyGram, Credit Card, PayPal, Westem Union, Cash, Escrow
Contact Suppliers

Follow this Suppliers