For Euchner LCA 2 Series Safety Light Curtain Replacement 40 mm Resolution | 12 m Operating Range | 160 mm to 1810 mm Protective Height

  • group nameEuchner Safety Light Curtains Replacement

  • Min Order1 piece

  • brand nameDADISICK

  • modelLCA 2 Series | LCA-2TR-40-160, LCA-2TR-40-310, LCA-2TR-40-460, LCA-2TR-40-610, LCA-2TR-40-760, LCA-2TR-40-910, LCA-2TR-40-1060, LCA-2TR-40-1210, LCA-2TR-40-1360, LCA-2TR-40-1510, LCA-2TR-40-1660, LCA-2TR-40-1810

  • payment methodT/T

  • update timeFri, 01 Nov 2024 11:40:47 GMT

Paramtents

  • Series: LCA 2 Series

  • Resolution: 40 mm

  • Scanning range: 12 m

  • Protective field height: 160 mm - 1810 mm

  • 2 Safety outputs (OSSD): 2 PNP

  • Response time: 4 ms - 16 ms

  • Connection type: M12

  • Security level: PLe2

Packging & Delivery

  • Min Order1 piece

Briefing

DADISICK is a professional manufacturer of safety sensors with solid product manufacturing capabilities.

Detailed

For Euchner LCA 2 Series Safety Light Curtain Replacement Parameter
Brand
From network
DADISICK
Models
LCA-2TR-40-160
LCA-2TR-40-310
LCA-2TR-40-460
LCA-2TR-40-610
LCA-2TR-40-760
LCA-2TR-40-910
LCA-2TR-40-1060
LCA-2TR-40-1210
LCA-2TR-40-1360
LCA-2TR-40-1510
LCA-2TR-40-1660
LCA-2TR-40-1810
Beam spacing
40 mm
40 mm
Protected altitude
160 mm, 310 mm, 460 mm, 610 mm, 
760 mm, 910 mm, 1060 mm, 1210 mm, 
1360 mm, 1510 mm, 1660 mm,1810 mm
120 mm, 280 mm, 440 mm, 600 mm, 
760 mm, 920 mm, 1080 mm,1160 mm, 
1320 mm,1480 mm,1640 mm, 1800 mm
Scanning range
12 m
0.3 m - 15 m
Response time
4 ms - 16 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65 / IP67
IP65
Connector
M12
M16
Housing cross-section
28 mm × 30 mm
35 mm × 51 mm
Safety Certificate
TÜV, UL
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Euchner's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK Safety Light Curtains
Model:
QT04-40-120-2BD, QT08-40-280-2BD, QT12-40-440-2BD, QT16-40-600-2BD, QT20-40-760-2BD, QT24-40-920-2BD, QT28-40-1080-2BD, QT30-40-1160-2BD, QT34-40-1320-2BD, QT38-40-1480-2BD, QT42-40-1640-2BD, QT46-40-1800-2BD

FAQ
What are the requirements for the working environment of safety light curtains?
The requirements for the working environment of safety light curtains include:

1.Temperature: The environmental temperature should be within the range of -10℃ to 55℃. Excessive temperatures, either too high or too low, may affect the normal operation of the safety light curtain.
2.Humidity: The air relative humidity should not exceed 95%. High humidity may cause condensation on the optical components, affecting their performance.
3.Media: The air should be free of media that can trigger explosions or corrode metals and damage insulation.
4.Vibration: The vibration amplitude and corresponding frequency should conform to national standards. Excessive vibration may damage internal components of the safety light curtain.
5.Lighting: Direct sunlight or other strong light sources should be avoided, as they may interfere with the detection accuracy of the safety light curtain.
6.Dust and dirt: Environments with excessive dust or dirt may accumulate on the optical surfaces of the safety light curtain, reducing its transmission efficiency. Regular cleaning and maintenance are required.
7.Reflective surfaces: Surfaces that can reflect light should be avoided in the vicinity of the safety light curtain, as reflected light may interfere with its operation.
8.Interference sources: The installation location should be free of interference sources that can affect the signal transmission of the safety light curtain, such as electromagnetic fields.
9.Space: The installation space should allow for the correct alignment and adjustment of the transmitter and receiver units of the safety light curtain.

It is important to note that the specific requirements for the working environment of safety light curtains may vary depending on the model, manufacturer, and intended application. It is recommended to consult the manufacturer's specifications and installation instructions for detailed information.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QT Series Data Sheet
Safety-light-curtain QT Series User Manual