LS-S Series 23mm Resolution 10m Sensing Distance SLLE23 and SLLR23 and SLLP23 Infrared Safety Light Curtain Replacement

  • group nameBANNER Safety Light Curtains Replacement

  • Min Order1 piece

  • brand nameDADISICK

  • modelLS-S Series | SLLP23-1960L/SLLE23-1960L-S/SLLR23-1960L-S, SLLP23-2100L/SLLE23-2100L-S/SLLR23-2100L-S, SLLP23-2380L/SLLE23-2380L-S/SLLR23-2380L-S

  • payment methodT/T

  • update timeFri, 08 Nov 2024 16:54:33 GMT

Paramtents

  • Series: LS-S Series

  • Resolution: 23mm

  • Scanning range: 0.1-10m

  • Protective field height: 1960-2380mm

  • 2 Safety outputs (OSSD): 2 PNP

  • Response time: 28.6-33.7ms

  • Connection type: M12

  • Security level: UL, CE, PLe4

Packging & Delivery

  • Min Order1 piece

Briefing

DADISICK is a professional manufacturer of safety sensors with solid product manufacturing capabilities.

Detailed

LS-S Series 23mm Resolution 10m Sensing Distance SLLE23 and SLLR23 and SLLP23 Infrared Safety Light Curtain Replacement Parameter
Brand
From network
DADISICK
Models
Emitter
Receiver
Pair
SLLE23-1960L-S
SLLR23-1960L-S
SLLP23-1960L
SLLE23-2100L-S
SLLR23-2100L-S
SLLP23-2100L
SLLE23-2380L-S
SLLR23-2380L-S
SLLP23-2380L
Beam spacing
23mm
20mm
Protected altitude
1960mm/2100mm/2380mm
1940mm/2100mm/2380mm
Scanning range
0.1-10m
0.3-10m
Response time
28.6-33.7ms
≤15ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65/IP67
IP65
Connector
M12
M16
Housing cross-section
36 x 45mm
51 x 35mm
Safety Certificate
UL, CE, PLe4
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The product models displayed on this page are only used to describe and compare the characteristics, specifications, and performance of different products. These models do not represent recommendations or associations for any specific brand or company. When users choose products, please understand and compare the detailed information of each brand's products on your own.
Product recommendations
DADISICK Safety Light Curtain
Model:
QMT98/20-1940 2BC, QMT106/20-2100 2BC, QMT120/20-2380 2BC

FAQ
What is the Difference Between Level 2 Safety Light Curtain and Level 4 Safety Light Curtain?

Level 2 safety light curtains have the following characteristics:
1. Low cost: Level 2 safety light curtains are generally affordable compared to higher-level light curtains.
2. Performance: Level 2 light curtains typically utilize a single CPU processor for their operation.
3. Dual safety channel outputs: They provide two separate output channels for enhanced safety redundancy and reliability4. Self-diagnosis or external periodic testing: Level 2 light curtains can perform self-diagnosis or be externally tested at regular intervals to check for any faults or malfunctions.
5. Fault exclusion method for safety performance: These light curtains employ fault exclusion techniques to ensure that they maintain their safety performance even in the presence of potential faults or failures.
6. Application range: Level 2 safety light curtains are suitable for use in situations or machines where the risk of injury is moderate or low. They are commonly used in automated production equipment, material handling devices, and similar applications.
Level 4 safety light curtains have the following characteristics:
1. Higher cost: Level 4 safety light curtains are generally more expensive compared to lower-level light curtains due to their advanced features and performance.
2. Performance: Level 4 light curtains typically utilize dual CPU processors for increased processing power and reliability.
3. Dual safety channel outputs: Similar to level 2 light curtains, they provide two separate output channels for enhanced safety redundancy and reliability.
4. More reliable control, less susceptible to interference: Level 4 light curtains are designed to be less affected by ambient light or other sources of interference, ensuring more reliable operation.
5. Self-diagnosis and advanced fault detection: They incorporate self-diagnosis capabilities for fault checking and may have additional features such as higher-level redundant fault cross-checking.
6. Application range: Level 4 safety light curtains are suitable for use in high-risk environments or machines where the potential for serious injury is greater. They provide effective protection for dangerous areas.

Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
Punch Press Safety-Light-Curtain Cable Description
signal output selection (actual output of transistor working normally)
Safety Grating Signal Output Selection
NPN output wiring diagram
Safety Curtain NPN Output Wiring Diagram
PNP output wiring diagram
Light Barrier PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Light Barriers Dimension
Safety-light-curtain QMT series-data sheet
Safety-light-curtain QMT series user manual