  • group nameRFG425 Series Safety Light Curtain Sensor Replacement

  • Min Order1 piece

  • brand nameDADISICK

  • modelRFG425 Series | RFG425-1580FL1, RFG425-1740FL1, RFG425-1900FL1, RFG425-2060FL1, RFG425-2260FL1, RFG425-2460FL1

  • payment methodT/T

  • update timeSat, 29 Jun 2024 12:38:57 GMT

Paramtents

  • Series: RFG425 Series

  • Resolution: 20 mm

  • Scanning range: 0.3 - 20 m

  • Protective field height: 1540 - 2420 mm

  • 2 Safety outputs (OSSD): 2 PNP

  • Response time: 10 - 21 ms

  • Connection type: M12

  • security level: PLe4

Packging & Delivery

  • Min Order1 piece

Briefing

DADISICK is a professional manufacturer of safety sensors with solid product manufacturing capabilities.

Detailed

RFG425 Series 20 mm Resolution 20 m Sensing Distance 1540 mm to 2420 mm Protective Height Extended Light Curtain Replacement Parameter
Brand
From network
DADISICK
Models
RFG425-1580FL1
QMT78-20-1540 2BE
RFG425-1740FL1
QMT86-20-1700 2BE
RFG425-1900FL1
QMT94-20-1860 2BE
RFG425-2060FL1
QMT102-20-2020 2BE
RFG425-2260FL1
QMT112-20-2220 2BE
RFG425-2460FL1
QMT122-20-2420 2BE
Beam spacing
20 mm
20 mm
Protected altitude
1540 mm, 1700 mm, 1860 mm, 2020 mm, 2220 mm, 2420 mm
1540 mm, 1700 mm, 1860 mm, 2020 mm, 2220 mm, 2420 mm
Scanning range
0.3 - 20 m
0.3 - 20 m
Response time
10 ms - 21 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65
IP65
Connector
M12
M16
Housing cross-section
32 mm x 38 mm
51 mm x 35 mm
Safety Certificate
CE, UL
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The product models displayed on this page are only used to describe and compare the characteristics, specifications, and performance of different products. These models do not represent recommendations or associations for any specific brand or company. When users choose products, please understand and compare the detailed information of each brand's products on your own.
Product recommendations
DADISICK QMT Series Machine Light Curtains
Model:
QMT78-20-1540 2BE, QMT86-20-1700 2BE, QMT94-20-1860 2BE
QMT102-20-2020 2BE, QMT112-20-2220 2BE, QMT122-20-2420 2BE








FAQ
Q:what is the difference between a level 2 safety light curtain and lever 4 safety light curtain ?
A:
Level 2 safety light curtains have the following characteristics:

1. Low cost: Level 2 safety light curtains are generally affordable compared to higher level light curtains.

2. Performance: Level 2 light curtains typically utilize a single CPU processor for their operation.

3. Dual safety channel outputs: They provide two separate output channels for enhanced safety redundancy and reliability4. Self-diagnosis or external periodic testing: Level 2 light curtains can perform self-diagnosis or be externally tested at regular intervals to check for any faults or malfunctions.

5. Fault exclusion method for safety performance: These light curtains employ fault exclusion techniques to ensure that they maintain their safety performance even in the presence of potential faults or failures.

6. Application range: Level 2 safety light curtains are suitable for use in situations or machines where the risk of injury is moderate or low. They are commonly used in automated production equipment, material handling devices, and similar applications.

Level 4 safety light curtains have the following characteristics:
1. Higher cost: Level 4 safety light curtains are generally more expensive compared to lower level light curtains due to their advanced features and performance.
2. Performance: Level 4 light curtains typically utilize dual CPU processors for increased processing power and reliability.
3. Dual safety channel outputs: Similar to level 2 light curtains, they provide two separate output channels for enhanced safety redundancy and reliability.
4. More reliable control, less susceptible to interference: Level 4 light curtains are designed to be less affected by ambient light or other sources of interference, ensuring more reliable operation.
5. Self-diagnosis and advanced fault detection: They incorporate self-diagnosis capabilities for fault checking and may have additional features such as higher-level redundant fault cross-checking.
6. Application range: Level 4 safety light curtains are suitable for use in high-risk environments or machines where the potential for serious injury is greater. They provide effective protection for dangerous areas.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Safety Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Safety Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Safety Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension