SLC240COM Series 14 mm Resolution 6 m Sensing Distance 1530 mm to 1930 mm Protective Height Safety Light Curtain Replacement

  • group nameSCHMERSAL Safety Light Curtains Replacement

  • Min Order1 piece

  • brand nameDADISICK

  • modelSLC240COM Series | SLC240COM-ER-1530-14, SLC240COM-ER-1610-14, SLC240COM-ER-1690-14, SLC240COM-ER-1770-14, SLC240COM-ER-1850-14, SLC240COM-ER-1930-14

  • payment methodT/T

  • update timeFri, 08 Nov 2024 09:12:47 GMT

Paramtents

  • Series SLC240COM Series

  • Resolution: 14 mm

  • Scanning range: 0.3 - 6 m

  • Protective field height: 1530 - 1930 mm

  • 2 Safety outputs (OSSD): 2 PNP

  • Response time: 28 ms

  • Connection type: M12

  • Security level: PLc2

Packging & Delivery

  • Min Order1 piece

Briefing

DADISICK is a professional manufacturer of safety sensors with solid product manufacturing capabilities.

Detailed

SLC240COM Series 14 mm Resolution 6 m Sensing Distance 1530 mm to 1930 mm Protective Height Safety Light Curtain Replacement Parameter
Brand
From network
DADISICK
Models
SLC240COM-ER-1530-14
QM154-10-1530 2BB
SLC240COM-ER-1610-14
QM162-10-1610 2BB
SLC240COM-ER-1690-14
QM170-10-1690 2BB
SLC240COM-ER-1770-14
QM178-10-1770 2BB
SLC240COM-ER-1850-14
QM186-10-1850 2BB
SLC240COM-ER-1930-14
QM194-10-1930 2BB
Beam spacing
14 mm
10 mm
Protected altitude
1530 mm, 1610 mm, 1690 mm, 1770 mm, 1850 mm, 1930 mm
1530 mm, 1610 mm, 1690 mm, 1770 mm, 1850 mm, 1930 mm
Scanning range
0.3 - 6 m
0.3 - 6 m
Response time
28 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP67
IP65
Connector
M12
M12
Housing cross-section
33 mm x 27.8 mm
36 mm x 36 mm
Safety Certificate
TÜV, UL
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The product models displayed on this page are only used to describe and compare the characteristics, specifications, and performance of different products. These models do not represent recommendations or associations for any specific brand or company. When users choose products, please understand and compare the detailed information of each brand's products on your own.
Product recommendations
DADISICK QM Series Machine Light Curtains
Model:
QM154-10-1530 2BB, QM162-10-1610 2BB, QM170-10-1690 2BB
QM178-10-1770 2BB, QM186-10-1850 2BB, QM194-10-1930 2BB




FAQ
Q:what is the difference between a level 2 safety light curtain and lever 4 safety light curtain ?

A:
Level 2 safety light curtains have the following characteristics:

1. Low cost: Level 2 safety light curtains are generally affordable compared to higher level light curtains.

2. Performance: Level 2 light curtains typically utilize a single CPU processor for their operation.

3. Dual safety channel outputs: They provide two separate output channels for enhanced safety redundancy and reliability4. Self-diagnosis or external periodic testing: Level 2 light curtains can perform self-diagnosis or be externally tested at regular intervals to check for any faults or malfunctions.

5. Fault exclusion method for safety performance: These light curtains employ fault exclusion techniques to ensure that they maintain their safety performance even in the presence of potential faults or failures.

6. Application range: Level 2 safety light curtains are suitable for use in situations or machines where the risk of injury is moderate or low. They are commonly used in automated production equipment, material handling devices, and similar applications.

Level 4 safety light curtains have the following characteristics:
1. Higher cost: Level 4 safety light curtains are generally more expensive compared to lower level light curtains due to their advanced features and performance.
2. Performance: Level 4 light curtains typically utilize dual CPU processors for increased processing power and reliability.
3. Dual safety channel outputs: Similar to level 2 light curtains, they provide two separate output channels for enhanced safety redundancy and reliability.
4. More reliable control, less susceptible to interference: Level 4 light curtains are designed to be less affected by ambient light or other sources of interference, ensuring more reliable operation.
5. Self-diagnosis and advanced fault detection: They incorporate self-diagnosis capabilities for fault checking and may have additional features such as higher-level redundant fault cross-checking.
6. Application range: Level 4 safety light curtains are suitable for use in high-risk environments or machines where the potential for serious injury is greater. They provide effective protection for dangerous areas.

Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Safety Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Safety Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Safety Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension