EZ-SCREEN LS Series Type 4 Heavy-Duty Safety Light Curtain Replacement 8-pin M12 Pigtail QD 40 mm Resolution | 12 m Operating Range | 350 mm to 1820 mm Protective Height

  • group nameTurck Safety Light Curtains Replacement

  • Min Order1 piece

  • brand nameDADISICK

  • modelEZ-SCREEN LS Series | SLLCP40-350P88, SLLCP40-420P88, SLLCP40-490P88, SLLCP40-560P88, SLLCP40-630P88, SLLCP40-700P88, SLLCP40-770P88, SLLCP40-840P88, SLLCP40-910P88, SLLCP40-980P88, SLLCP40-1050P88, SLLCP40-1120P88, SLLCP40-1190P88, SLLCP40-1260P88, SLLCP40-1330P88, SLLCP40-1400P88, SLLCP40-1470P88, SLLCP40-1540P88, SLLCP40-1610P88, SLLCP40-1680P88, SLLCP40-1750P88, SLLCP40-1820P88, SLLCR40-350P8, SLLCR40-420P8, SLLCR40-490P8, SLLCR40-560P8, SLLCR40-630P8, SLLCR40-700P8, SLLCR40-770P8, SLLCR40-840P8, SLLCR40-910P8, SLLCR40-980P8, SLLCR40-1050P8, SLLCR40-1120P8, SLLCR40-1190P8, SLLCR40-1260P8, SLLCR40-1330P8, SLLCR40-1400P8, SLLCR40-1470P8, SLLCR40-1540P8, SLLCR40-1610P8, SLLCR40-1680P8, SLLCR40-1750P8, SLLCR40-1820P8, SLLCE40-350P8, SLLCE40-420P8, SLLCE40-490P8, SLLCE40-560P8, SLLCE40-630P8, SLLCE40-700P8, SLLCE40-770P8, SLLCE40-840P8, SLLCE40-910P8, SLLCE40-980P8, SLLCE40-1050P8, SLLCE40-1120P8, SLLCE40-1190P8, SLLCE40-1260P8, SLLCE40-1330P8, SLLCE40-1400P8, SLLCE40-1470P8, SLLCE40-1540P8, SLLCE40-1610P8, SLLCE40-1680P8, SLLCE40-1750P8, SLLCE40-1820P8

  • payment methodT/T

  • update timeFri, 08 Nov 2024 16:55:05 GMT

Paramtents

  • Series: EZ-SCREEN LS Series

  • Resolution: 40 mm

  • Scanning range: 0.1 m - 12 m

  • Protective field height: 350 mm - 1820 mm

  • 2 Safety outputs (OSSD): 2 PNP

  • Response time: 8.2 ms - 15.9 ms

  • Connection type: M12

  • Security level: PLe4

Packging & Delivery

  • Min Order1 piece

Briefing

DADISICK is a professional manufacturer of safety sensors with solid product manufacturing capabilities.

Detailed

EZ-SCREEN LS Series Type 4 Heavy-Duty Safety Light Curtain Replacement Parameter
Pair
Receiver
Emitter
DADISICK
SLLCP40-350P88
SLLCR40-350P8
SLLCE40-350P8
QT10-40-360-2BD
SLLCP40-420P88
SLLCR40-420P8
SLLCE40-420P8
QT12-40-440-2BD
SLLCP40-490P88
SLLCR40-490P8
SLLCE40-490P8
QT14-40-520-2BD
SLLCP40-560P88
SLLCR40-560P8
SLLCE40-560P8
QT14-40-520-2BD
SLLCP40-630P88
SLLCR40-630P8
SLLCE40-630P8
QT16-40-600-2BD
SLLCP40-700P88
SLLCR40-700P8
SLLCE40-700P8
QT18-40-680-2BD
SLLCP40-770P88
SLLCR40-770P8
SLLCE40-770P8
QT20-40-760-2BD
SLLCP40-840P88
SLLCR40-840P8
SLLCE40-840P8
QT22-40-840-2BD
SLLCP40-910P88
SLLCR40-910P8
SLLCE40-910P8
QT24-40-920-2BD
SLLCP40-980P88
SLLCR40-980P8
SLLCE40-980P8
QT26-40-1000-2BD
SLLCP40-1050P88
SLLCR40-1050P8
SLLCE40-1050P8
QT28-40-1080-2BD
SLLCP40-1120P88
SLLCR40-1120P8
SLLCE40-1120P8
QT28-40-1080-2BD
SLLCP40-1190P88
SLLCR40-1190P8
SLLCE40-1190P8
QT30-40-1160-2BD
SLLCP40-1260P88
SLLCR40-1260P8
SLLCE40-1260P8
QT32-40-1240-2BD
SLLCP40-1330P88
SLLCR40-1330P8
SLLCE40-1330P8
QT34-40-1320-2BD
SLLCP40-1400P88
SLLCR40-1400P8
SLLCE40-1400P8
QT36-40-1400-2BD
SLLCP40-1470P88
SLLCR40-1470P8
SLLCE40-1470P8
QT38-40-1480-2BD
SLLCP40-1540P88
SLLCR40-1540P8
SLLCE40-1540P8
QT40-40-1560-2BD
SLLCP40-1610P88
SLLCR40-1610P8
SLLCE40-1610P8
QT42-40-1640-2BD
SLLCP40-1680P88
SLLCR40-1680P8
SLLCE40-1680P8
QT42-40-1640-2BD
SLLCP40-1750P88
SLLCR40-1750P8
SLLCE40-1750P8
QT44-40-1720-2BD
SLLCP40-1820P88
SLLCR40-1820P8
SLLCE40-1820P8
QT46-40-1800-2BD
Beam spacing
40 mm
40 mm
Protected altitude
350 mm, 420 mm, 490 mm, 560 mm, 
630 mm, 700 mm, 770 mm, 840 mm, 
910 mm, 980 mm, 1050 mm, 1120 mm, 
1190 mm, 1260 mm, 1330 mm, 1400 mm, 
1470 mm, 1540 mm, 1610 mm, 1680 mm, 
1750 mm, 1820 mm
360 mm, 440 mm, 520 mm, 520 mm, 
600 mm, 680 mm, 760 mm, 840 mm, 
920 mm, 1000 mm, 1080 mm, 1080 mm, 
1160 mm, 1240 mm, 1320 mm, 1400 mm, 
1480 mm, 1560 mm, 1640 mm, 1640 mm, 
1720 mm, 1800 mm
Scanning range
0.1 m - 12 m
0.3 m - 15 m
Response time
8.2 ms - 15.9 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65 / IP67
IP65
Connector
M12
M16
Housing cross-section
45 mm × 36 mm
35 mm × 51 mm
Safety Certificate
cULus, CE
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The product models displayed on this page are only used to describe and compare the characteristics, specifications, and performance of different products. These models do not represent recommendations or associations for any specific brand or company. When users choose products, please understand and compare the detailed information of each brand's products on your own.
Product recommendations
DADISICK Safety Light Curtains
Model:
QT10-40-360-2BD, QT12-40-440-2BD, QT14-40-520-2BD, QT14-40-520-2BD, QT16-40-600-2BD, QT18-40-680-2BD, QT20-40-760-2BD, QT22-40-840-2BD, QT24-40-920-2BD, QT26-40-1000-2BD, QT28-40-1080-2BD, QT28-40-1080-2BD, QT30-40-1160-2BD, QT32-40-1240-2BD, QT34-40-1320-2BD, QT36-40-1400-2BD, QT38-40-1480-2BD, QT40-40-1560-2BD, QT42-40-1640-2BD, QT42-40-1640-2BD, QT44-40-1720-2BD, QT46-40-1800-2BD

FAQ
How do safety light curtains prevent guard gaps?
Safety light curtains prevent guard gaps in several ways:

1.Continuous Detection Zone: Safety light curtains create a continuous detection zone using multiple infrared beams. This zone is adjustable in height and width to cover the entire area that needs to be guarded.
2.No Dead Zones: Unlike other guarding devices, safety light curtains do not have dead zones where objects can pass undetected. The multiple beams ensure that any object, regardless of its size, shape, or orientation, will be detected if it passes through the light curtain.
3.Adjustable Resolution: The resolution of the safety light curtain, which determines the spacing between individual beams, can be adjusted. By reducing the beam spacing, a finer detection zone can be created, effectively eliminating small gaps that could allow objects to pass undetected.
4.Rapid Response Time: Safety light curtains have a very fast response time, typically in milliseconds. This means that as soon as an object interrupts one or more beams, the safety light curtain will immediately send a signal to stop the hazardous machine movement.
5.Redundancy: Many safety light curtain systems feature redundancy, meaning they have multiple layers of detection. If one beam is interrupted, the system will not necessarily stop the machine, but if multiple beams are interrupted, indicating a larger object, the system will trigger an emergency stop.
6.Monitoring and Diagnostics: Modern safety light curtain systems often include monitoring and diagnostic features that can detect when a beam is malfunctioning or if there is a gap in the detection zone. This allows for prompt maintenance and repair, ensuring the system's continued effectiveness.

By creating a continuous and adjustable detection zone with no dead zones, safety light curtains effectively prevent guard gaps, making them an effective safety solution for many industrial applications.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QT Series Data Sheet